Specification
Oxygen concentration | 93% ± 3% |
Oxygen output | 1-10L |
Oxygen pressure | 0.04-0.07Mpa |
Oxygen generation method | PSA |
Size | 14.3×14.7×23.6 inches |
Weight | 27kg |
Operating noise | ≤55db |
Function | Oxygen generation + atomization |
Power consumption (Watts) | 650W |
Oxygen flow | Continuous flow |
Warranty | 1 year |
Alarm | Power failure alarm; high and low voltage alarm; high temperature alarm |
Product Features

Stable Oxygen Concentration
This oxygen concentrator provides 1-10 adjustable flow settings and maintains 93% ±3% oxygen concentration at all flow levels and operating modes, ensuring a pure and reliable oxygen care experience.

Oxygen Generation + Atomization
The oxygen concentrator + nebulizer two-in-one adopts micron-level atomization. With only one investment, it can meet two treatment needs at the same time, saving the trouble of purchasing additional equipment.

Comprehensive Intelligent Alarm System
PO: Power switch (green light)
PF: Power failure (red light)
HP: High pressure (red light)
LP: Low pressure (yellow light)
HT: Overheat temperature (red light)
H.O₂: Oxygen purity ≥ 85%, (blue light) (accuracy: ±3%)
LO₂: Oxygen purity < 85%, (red light) (accuracy: ±3%)

LCD Screen
The clear display can show real-time machine performance data, such as: air pressure, temperature, current usage time, cumulative usage time, etc. The two buttons below the screen can be used for timing and subtraction. Each press of the left (△) button increases the timing by 10 minutes, and the maximum timing is 40 hours. Each press of the right (▽) button decreases the timing by 10 minutes. When the timing is reduced to “0”, the oxygen concentrator automatically shuts down. (The LCD screen lights up when the machine is turned on, and returns to the screen saver mode after 15 minutes. Press the right button during operation and the screen lights up again.)

Low-noise Technology
This oxygen concentrator uses ultra-quiet drive technology to ensure that the noise level is stable at 50-55 decibels. It produces oxygen efficiently while maintaining low noise operation, allowing you to sleep peacefully.

Ten-level Filtration
This oxygen concentrator uses a 10-layer filtration system, including Grobrock filter, Dichter filter, HEPA filter, medical filter material, molecular filtration, oxygen separation, oxygen concentration, antibacterial, etc. The comprehensive filtration system can effectively remove bacteria and inhalable particles to ensure the output of pure and odorless oxygen.

Oil-free Compressor
It can prevent lubricating oil from contaminating oxygen, ensure gas purity, and eliminate the need for lubrication and maintenance. It can reduce energy consumption and component wear, and improve oxygen production efficiency and equipment applicability.

High Efficiency Molecular Sieve Technology
Imported molecular sieves use zeolite molecular sieves with uniform particle size and small pore size to quickly screen nitrogen, carbon dioxide and other gases in the air, separate oxygen, and continuously and stably output high-concentration oxygen.
Meeting the Oxygen Therapy Needs of Different Groups of People

Patients with chronic respiratory diseases (such as COPD, asthma):Such patients are prone to shortness of breath and wheezing during daily activities (such as climbing stairs and doing housework), and in severe cases, they also feel labored breathing even at rest. They have obvious chest tightness, accompanied by persistent coughing (especially worse in the morning and evening), and some patients cough up more sputum. Our oxygen concentrator maintains an oxygen concentration of 93%±3% at a flow rate of 1-10L/min, which can quickly increase blood oxygen saturation and reduce the feeling of labored breathing. In mild symptoms, low flow (1-3L/min) maintains basic oxygen supply, which can be increased to 5-10L/min during acute attacks to meet emergency oxygen supply needs.
Oxygen concentrator + nebulizer two-in-one can simultaneously relieve bronchospasm during asthma attacks, which is more effective in controlling symptoms than oxygen therapy alone, avoiding the purchase of additional nebulizer equipment.

Primary medical institutions:If grassroots hospitals install a central oxygen supply system, they need to invest in pipeline laying, gas tanks and other facilities, which have high initial costs and a long construction period. Our oxygen concentrator uses PSA pressure swing adsorption technology, which can generate oxygen by plugging in, without complex infrastructure, and is suitable for rapid deployment in grassroots hospitals with limited budgets. With the power failure alarm function (the red light is on when the power is off), it can remind you to switch to the backup power supply when the power is off, ensuring uninterrupted oxygen therapy for emergency or hospitalized patients.
Our oxygen concentrator does not need to be connected to the nebulizer equipment separately, and can directly administer drugs through the nebulizer interface, reducing equipment procurement costs (avoiding the purchase of oxygen concentrators and nebulizers separately) and simplifying the treatment process.

People in high altitude environment(tourists, mountaineering enthusiasts, etc.): The air pressure in plateau areas (especially above 2,000 meters above sea level) is significantly reduced, and the molecular sieve adsorption efficiency of ordinary oxygen concentrators is greatly reduced. The oxygen concentration may decay to below 70%, which cannot meet the treatment needs. Our oxygen concentrator can maintain an oxygen concentration of 93%±3% at an altitude of 5,500 meters, ensuring the oxygen therapy effect in high-altitude areas. The flow range is adjustable from 1 to 10L/min. Patients with mild altitude sickness use 3-5L/min to prevent hypoxia, and severe patients use 8-10L/min for emergency treatment, realizing “one device covers all scenarios”. Our oxygen concentrator is equipped with a ten-layer filter to effectively intercept plateau dust and particulate matter, reduce compressor and molecular sieve wear, and extend equipment life. The use of food-grade humidification cups imported from the United States can moisten oxygen, alleviate the irritation of the dry climate on the respiratory tract, reduce the risk of respiratory tract infection, and improve the comfort of oxygen inhalation.

Athletes and sports training institutions:Athletes can simulate a low oxygen environment to improve training effects. By adjusting the flow rate (1-10L/min) and using a low oxygen mask, they can simulate hypoxia at different altitudes, promote red blood cell production, and enhance endurance. In a low oxygen environment, the kidneys sense the decrease in blood oxygen partial pressure, release erythropoietin (EPO), and stimulate the bone marrow to produce more red blood cells. Studies have shown that 2-4 weeks of low oxygen training can increase the number of red blood cells by 5%-10%, significantly improve the blood’s oxygen carrying capacity, and thus extend the fatigue critical point of athletes in endurance events (such as long-distance running and swimming). After high-intensity training, the accumulation of lactic acid in the muscles is one of the main causes of fatigue. The high-flow oxygen inhalation of 8-10L/min from the oxygen concentrator can quickly increase the blood oxygen saturation to more than 95%, accelerate the decomposition of lactic acid by aerobic metabolism, and shorten the recovery cycle. Our oxygen concentrator maintains an oxygen concentration of 93%±3% within the flow range of 1-10L/min, avoiding oxygen concentration fluctuations caused by flow adjustment, ensuring the consistency of low oxygen stimulation intensity, and preventing deviations in training effects.

People troubled by air pollution and haze: PM2.5 and harmful gases (such as formaldehyde, carbon monoxide, etc.) adhere to the respiratory tract, affecting the oxygen exchange efficiency of the alveoli, and indirectly causing hypoxia in the body. Our oxygen concentrator is equipped with an 10-layer filter to purify the air before oxygen production, reduce the inhalation of pollutants, and improve the purity of oxygen. After inhalation, it can accelerate the discharge of harmful substances in the body (such as the combination of carbon monoxide and hemoglobin) and relieve respiratory inflammation (such as coughing and asthma). 1-10 liters of adjustable flow oxygen is suitable for daily protection to emergency needs when breathing is difficult, and 93%±3% high-concentration oxygen can effectively improve the quality of inhaled oxygen, reduce the stimulation of harmful substances and relieve respiratory hypoxia.
Product Details

Imported food-grade humidifier bottles are used to humidify oxygen to prevent dry oxygen from irritating the throat and nasal mucosa. If you feel that the oxygen is dry, pour an appropriate amount of pure water into the humidifier bottle. The water level should be between the highest and lowest scale lines of the humidifier bottle.

The flow rate is adjustable from 1 to 10L, and the operation is simple. Just turn it to adjust. Turn counterclockwise to open, and turn clockwise to close.

The detachable filter on the side is convenient for users to remove and clean or replace regularly. Users can remove the filter by themselves according to the frequency of use and environmental conditions, and remove pollutants attached to the filter by simple water washing, vacuuming, etc., to maintain the good filtering performance of the filter.

The bottom is equipped with four braked universal pulleys, which are wear-resistant and durable, with low rolling noise. Whether on a smooth tile floor or a slightly undulating wooden floor, it can easily achieve operations such as translation, steering, and diagonal movement, greatly improving the mobility and convenience of the equipment.

The top is equipped with a hidden storage cabinet, which can be used to store oxygen tubes for easy storage.

There is a hidden handle on the side to facilitate users to move the oxygen concentrator.

There is a socket at the bottom of the back of the machine, just connect it to the power supply and it can be used.
Application Scenarios

Clinic

Nursing home

Sports Training Center

Home

Hotels on the Plateau

Office
How to use?

1. Remove the humidification bottle in a clockwise direction. Inject an appropriate amount of pure water to between the highest and lowest scales, and then tighten the bottle.

2. Turn on the power supply, insert the power cord plug into the power socket of the oxygen concentrator; insert the other end of the power plug into the indoor power socket and turn on the power switch.

3. Adjust the oxygen output flow rate as needed. (Turn the flowmeter counterclockwise to open, and clockwise to close).

4. Insert the air inlet end of the oxygen tube into the outlet of the humidifier bottle, then put the oxygen tube on the ear of the person who wants to breathe oxygen, and insert the nose plug on the oxygen tube into the nostril of the person who wants to breathe oxygen;

5. When oxygen inhalation is finished, turn off the power. When not in continuous use, unplug the power plug.

1.Open the medicine cup cover, add the medicine to be atomized, and then close the cup cover.

2.Connect the interface of the atomizer nozzle (or mask) to the medicine cup cover, connect the other end of the atomizer connecting tube to the oxygen generator atomization outlet connector, and turn on the atomizer.

3.Turn on the power switch of the oxygen generator, adjust the flow meter to 0.5L/min, and then start atomization treatment.
Packing List

1×machine
1×air intake filtering net
1×air intake filtering cloth
1×power cord
1×user manual
1×nasal cannula

The packaging is in a protective carton with cushioning materials inside to ensure safe transportation. After unpacking, you can see the oxygen generator, nasal oxygen tube, instruction manual and other accessories. Follow the instructions to quickly install and use the device, providing you with a stable oxygen supply.
Transport and Storage Conditions
Ambient temperature range: -40~55℃
Relative humidity range: ≤95%
Air pressure range: 700-1060hpa
Certified


FAQ
It takes 18.5 minutes for the oxygen concentrator to warm up and reach normal function and nominal performance.
1. Check whether the humidifier bottle cap is installed, and check whether the bottle cap and humidifier bottle are leaking, and reinstall them;
2. Check whether the humidifier bottle seal ring is off;
3. Check whether the humidifier bottle is tightly connected to the machine;
4. Check whether the oxygen inhalation tube is bent or blocked.
72 hours.